In general, for basic unlighted single pole switches, the ON position closes the circuit at switch terminals 2 & 3. The ON-NONE-OFF or ON-OFF circuit is a maintained, single throw, two-position switch circuit. A double throw switch (DT) switch opens or closes a circuit at both extreme positions of its actuator, a common example being an ON-NONE-ON switch. A single throw switch (ST) opens or closes a circuit at only one of the extreme positions of its actuator, the most common example being an ON-NONE-OFF switch.
![momentary rocker switch on off on momentary rocker switch on off on](https://i.ebayimg.com/images/g/6JMAAOSwf0dcxXQG/s-l400.jpg)
Usually the number of "ON" positions that a switch has is the same as the number of throws. The throw of a switch is the number of circuit paths that can be controlled by any one pole. Therefore a normally closed circuit can also be referred to as "normally ON". momentary switch has one or more circuits that are closed when the switch actuator is at its normal or rest position. Therefore a normally open circuit can also be referred to as "normally OFF".Ī normally closed or N.C. An "open" circuit is an incomplete circuit, with "open space" between contacts. momentary switch has one or more circuits that are open when the switch actuator is at its normal or rest position. Momentary switches can be described as normally open or normally closed, which refers to the switch's original or at rest position. For example, the doorbell circuit would be represented as (ON)-NONE-OFF, where (ON) is the momentary position. A simple example of a momentary switch would be a doorbell, which automatically returns back to its resting "OFF" position when no longer actuated.Ĭarling Technologies' catalogs denote momentary circuits using parenthesis. For example, if switched to the "ON" position, the switch will remain in the "ON" position until it is physically switched to another position.Ī momentary switch is a "spring return" switch which automatically returns to its original or at rest position.
![momentary rocker switch on off on momentary rocker switch on off on](https://ae01.alicdn.com/kf/HTB1xjuSSFXXXXb8XFXXq6xXFXXXn/Momentary-SPDT-ON-OFF-ON-3-Position-Toggle-Switch-AC-250V-15A.jpg)
A maintained switch maintains the mode or position to which it is actuated. An open circuit will not conduct electricity because either air, or some other insulator has stopped or broken the flow of current in the loop.Ĭarling offers a wide range of circuit configurations with both maintained and momentary switch functions. A closed circuit allows an uninterrupted flow of electricity from the source of power, through the conductor or wire, to the load, and then back again to the ground or source of power. These Rocker Switches can be used for the American LaFrance Switches:Ī06-36027-034 (CRUISE SET/RESUME) Lens not included.Ġ675-000003-0034 (CRUISE SET/RESUME) Lens not included.Ī06-36027-039 (PLOW CONTROL) Lens not included.Ġ675-000003-0039 (PLOW CONTROL) Lens not included.Ī06-36027-049 (SIREN/BRAKE) Lens not included.Ġ675-000003-0049 (SIREN/BRAKE) Lens not included.A circuit is the closed loop through which electricity can flow. Images can be chosen from our image database under Switches – Reference Images in the top Menu Bar: Lights wired to Pin 9 (-) & 10 (+)( from Data Sheet Lamp Circuit Code H)
![momentary rocker switch on off on momentary rocker switch on off on](https://electrosome.com/wp-content/uploads/2012/12/Push-Button-Switch.jpg)
Power exits at 4 from Power Pin 2 and from 8 from Power Pin 6 during the momentary up switch position. Power exits at 1 from Power Pin 2 and from 5 from Power Pin 6 during the momentary down switch position. These switches are vibration, shock, thermoshock, moisture and salt spray resistant. Snap Mount for easy panel assembly: IP67 Certified Rocker Switch: Double pole that is Independent Momentary On on bottom, Off in the middle, and Momentary On on Top